From: Michael_Looby@sandwich.pfizer.com
Subject: Problem with multiple dose input
Date: 22 Oct 1997 12:59:53 -0400

Dear NONMEM users,

I would like to alert you to a problem I encountered recently which cost me some time and nerves. I am not sure what is going on, perhaps you may have some ideas.....

I was developing a model with simultaneous input into 2 compartments:

------------------------------------------
TIME  CON  AMT   RATE   CMT  EVID  MDV  SS  
------------------------------------------
0     0    5000  20000  1    1     1    0   
0     0    0     -1     3    1     1    1   
0     0    9999  -1     3    1     1    0   
------------------------------------------

The input to compartment 1 is an infusion at time 0, the input to compartment 3 is a steady-state infusion followed by a nonsteady-state infusion both also at time 0 and both of which have their rates estimated. Surprisingly (to me at least) this dosing code did not produce ANY input into either compartment.

After much trial and error I discovered that the following dosing code worked. For some reason I had to put the steady-state dose (into CMT 3) before the nonsteady-state doses into CMT 1 (or CMT 3).

------------------------------------------
TIME  CON  AMT   RATE   CMT  EVID  MDV  SS  
------------------------------------------
0     0    0     -1     3    1     1    1   
0     0    9999  -1     3    1     1    0   
0     0    5000  20000  1    1     1    0   
------------------------------------------

For me at least it is not intuitive that doses to different compartments should interfere with each other. I would be interested in hearing your comments.

Regards
Mick Looby

PFIZER CENTRAL RESEARCH
----------------------------------------------------------------
This message and any attachment has been virus checked by the
Pfizer Research Sandwich Data Centre.
----------------------------------------------------------------

****

From: Raymond Miller 301-443-8098 FAX 301-480-6645 <MILLERRAY@cder.fda.gov>
Subject: Re: Problem with multiple dose input
Date: 22 Oct 1997 14:48:09 -0400

Mick,

I believe the above code will work if you take into account that your first steady-state dose comes after a previous dose and therefore it should be a superimposed steady-state dose (even though it is into another compartment) i.e. the SS data item should be 2 not 1. See below.

------------------------------------------
TIME  CON  AMT   RATE   CMT  EVID  MDV  SS  
------------------------------------------
0     0    5000  20000  1    1     1    0   
0     0    0     -1     3    1     1    2   
0     0    9999  -1     3    1     1    0   
------------------------------------------

By recoding the dosing order you simply got around this problem in another way.

Raymond Miller

****

From: Lewis Sheiner <76135.526@compuserve.com>
Subject: Problem with multiple dose input
Date: 23 Oct 1997 03:31:17 -0400

Previous note:

> Dear NONMEM users,
>
> I would like to alert you to a problem I encountered recently which
> cost me some time and nerves. I am not sure what is going on, perhaps
> you may have some ideas.....
>
> I was developing a model with simultaneous input into 2 compartments:
>
> TIME CON AMT RATE CMT EVID MDV SS
> 0 0 5000 20000 1 1 1 0
> 0 0 0 -1 3 1 1 1
> 0 0 9999 -1 3 1 1 0
>
> The input to compartment 1 is an infusion at time 0, the input to
> compartment 3 is a steady-state infusion followed by a nonsteady-state
> infusion both also at time 0 and both of which have their rates
> estimated. Surprisingly (to me at least) this dosing code did not
> produce ANY input into either compartment.

ARE YOU SURE? I CAN SEE WHY THE FIRST RECORD PRODUCED NOTHING (SEE BELOW), BUT IT SEEMS TO ME THAT IF YOU MODELED R3 PROPERLY, YOU SHOULD HAVE SEEN THE RESULTS OF THE SECOND 2 LINES; THAT IS, THE SS INFUSION ENDING AT TIME 0 AND THEN THE SINGLE-DOSE INFUSION BEGINNING AT TIME 0, BOTH INTO CMPT 3. BUT MAYBE THERE'S SOMETHING MORE SUBTLE HERE THAT ESCAPES ME ...

> After much trial and error I discovered that the following dosing code
> worked. For some reason I had to put the steady-state dose (into CMT=
> 3) before the nonsteady-state doses into CMT 1 (or CMT 3).
>
> TIME CON AMT RATE CMT EVID MDV SS
> 0 0 0 -1 3 1 1 1
> 0 0 9999 -1 3 1 1 0
> 0 0 5000 20000 1 1 1 0
>
> For me at least it is not intuitive that doses to different
> compartments should interfere with each other. I would be interested
> in hearing your comments.

SS DOSES RESET THE SYSTEM (EXCEPT IF YOU MAKE SS =2, IN WHICH CASE THEY ADD THEIR SOLUTIONS INTO THE SYSTEM). THEREFORE, ANYTHING THAT PRECEEDS A SS RECORD WITH SS=1 DISAPPEARS. THIS IS APPRPRIATE.

HERE IS THE APPRPRIATE DISCUSSION FROM THE 'HELP' DOCUMENT:

SS labels PREDPP's steady-state (SS) data item. The steady-state data item is optional. It can take one of three values in any event record.

0 indicates that the dose is not a steady state dose.

1 indicates that the dose is a steady state dose, and that the compartment amounts are to be reset to the steady-state amounts resulting from the given dose. Compartment amounts resulting from prior doses into the system are "zeroed out," and infusions in progress or pending additional doses are cancelled. The system is not totally reset: the on/off status of the compartments remains as it was at the time of the prior event record (if any), and the value of time must be greater than or equal to its value on the prior event record (if any).

2 indicates that the dose is a steady state dose and that the compartment amounts are to be set to the sum of the steady-state amounts resulting from the given dose plus whatever those amounts would have been at the event time were the steady-state dose not given. I.e., letting t be the time on the event record, then the amounts in the compartments are updated to amounts valid for time t, and next, these amounts are added to the steady-state amounts. This is meaningful when kinetics are linear and the superposition principle holds.

****

From: Michael_Looby@sandwich.pfizer.com
Subject: Re: Problem with multiple dose input
Date: 23 Oct 1997 15:58:23 -0400

Lewis and Raymond,

thanks for your prompt and helpful replies; indeed setting SS=2 does solve the problem.

In reply to Lewis' first comment (see below) the first dosing data I presented (see below) does in fact produce input into compartment 3; in a fit of "nonmem rage" I had commented out an essential piece of code (ie my mistake).

In reply to the second comment, the first input data (see below) does in fact comply with SS=1 as defined in the "help" document. The dose into CMT 1 is not "prior" to the steady-state dose but is given at the same time (0 in this case). Furthermore, the reason I did not think of using SS=2 is the fact that I had (and still have) difficulty understanding the "help" text as it is written for this statement. Is this just me, or is this text a tad confusing?

Kind regards

Mick Looby

****

From: alison@c255.ucsf.EDU (ABoeckmann)
Subject: Problem with multiple dose input
Date: 28 Oct 1997 19:18:56 -0500

Probably you've all seen the email from Mick Looby re: multiple doses, and responses from Raymond Miller and Lewis Sheiner, so I won't repeat it.

The wording in Guide VIII/ on-line help as quoted by Lewis is:

1 indicates that the dose is a steady state dose, and that the compartment amounts are to be reset to the steady-state amounts resulting from the given dose. Compartment amounts resulting from prior doses into the system are "zeroed out," ... etc

Mick says:
The dose
into CMT 1 is not "prior" to the steady-state dose but is given at the same time (0 in this case). Furthermore, the reason I did not think of using SS=2 is the fact that I had (and still have) difficulty understanding the "help" text as it is written for this statement. Is this just me, or is this text a tad confusing?

By "prior" we mean "on prior event records", which perforce includes prior (smaller) time values, but also includes event records having the same value of TIME that are encountered previously in the data file.

Guide VIII/on-line help was never intended to be the sole source of information, but rather to be a brief summary for people to look up when they know pretty much how things work but have forgotten the details. In the case of Steady State dosing, the details and several examples are found in the referenced material, especially in Guide V:

REFERENCES: Guide VI, section V.F (p. 57)
REFERENCES: Guide V, section 6.8 (p. 57)

I'm truly sorry to read about "nonmem rage". NONMEM/PREDPP is a complicated system, and understandably there is bound to be some frustration at times. Maybe we can fix the wording in Guide VIII for the next release. Would it be more understandable if Guide VIII were changed as follows?

1 indicates that the dose is a steady state dose, and that the compartment amounts are to be reset to the steady-state amounts resulting from the given dose. Compartment amounts resulting from prior dose event records are "zeroed out," ... etc

^^^^^^^^^^^^^^^^^^^^^^^^

We are working on a new release of Guide VIII to accompany NONMEM V. If anyone has noticed mistakes, or has useful suggestions, this would be a good time to send them to me (nmconsult@c255.ucsf.edu). Needless to say, constructive suggestions are prefered to general remarks such as "unclear", "don't understand", etc.

Alison